Commit Graph
2 Commits
Author SHA1 Message Date
ew8bakandClaude Sonnet 4.6 cd0cf21876 Fix supply voltage display: correct constant per board type, hide on unsupported boards
Per Appendix A of openHPSDR Ethernet Protocol v4.3:
- Boards 1,2,3 (Hermes/Angelia): V = ADC/4095 * 3.3 (was always using this)
- Boards 4,5 (Orion/Orion MkII): V = ADC/4095 * 5.0 (was wrong, showing ~66% of real value)
- Board 0 (Atlas) has no supply voltage measurement per protocol spec
  ("not Atlas bus systems")
- Boards 6 (Hermes Lite), 10 (Saturn): constant not documented, hide Supply field

ADCToSupplyVolts now takes BoardType and returns -1.0 for unsupported boards.
DoUpdateStatus omits the Supply field when -1.0 is returned.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-27 22:06:27 +03:00
ew8bak 7521a46bbc init 2026-03-05 16:19:26 +03:00