feat: pluto telemetry — show both temperatures (transceiver + Zynq SoC)

Pluto exposes two temperature sensors: the AD9361 transceiver
(ad9361-phy temp0/input, milli-°C) and the Zynq SoC/FPGA (xadc temp0,
raw+offset+scale → C = (raw+offset)*scale/1000). Only the former was
read. Now both are read and shown as "Temp 37/53C" (chip/SoC) in the
desktop status bar and web UI.

- ReadTelemetry gains an out SocTempC param (base + Pluto override);
  Pluto reads xadc via the IIO context.
- Controller stores FLastPlutoSocTempC; SoC temp validated with a
  plausibility window (no slew-limit — stable local sensor, unlike the
  AD9361 sensor that spikes during mid-conversion).
- Status formatting handles one or both temps in MainForm and WebAdapter.
- Widen desktop status-bar field 3 (150→190) so both temps + RSSI fit;
  web layout unchanged.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
This commit is contained in:
2026-06-23 19:10:07 +03:00
co-authored by Claude Opus 4.8
parent 63c8c91152
commit 6375092741
6 changed files with 79 additions and 32 deletions
+9 -7
View File
@@ -154,9 +154,10 @@ type
procedure SetSpeakerAudio(AEnabled: Boolean); virtual;
// Аппаратная телеметрия, не приходящая в потоке (опрашивается контроллером).
// Pluto/AD936x: температура чипа (°C) и RSSI приёмника (дБ). HPSDR — нет такой
// (использует HP-status), возвращает False. Недоступные значения = TELEMETRY_NONE.
function ReadTelemetry(out TempC, RSSIdB: Double): Boolean; virtual;
// Pluto/AD936x: температура трансивера (TempC) и Zynq SoC/FPGA (SocTempC) в °C,
// RSSI приёмника (дБ). HPSDR — нет такой (использует HP-status), возвращает False.
// Недоступные значения = TELEMETRY_NONE.
function ReadTelemetry(out TempC, SocTempC, RSSIdB: Double): Boolean; virtual;
// ---- Свойства состояния (полиморфные через виртуальные геттеры) ----
property Connected: Boolean read GetConnected;
@@ -246,11 +247,12 @@ procedure TRadioBackend.SetSpeakerAudio(AEnabled: Boolean);
begin
end;
function TRadioBackend.ReadTelemetry(out TempC, RSSIdB: Double): Boolean;
function TRadioBackend.ReadTelemetry(out TempC, SocTempC, RSSIdB: Double): Boolean;
begin
TempC := TELEMETRY_NONE;
RSSIdB := TELEMETRY_NONE;
Result := False;
TempC := TELEMETRY_NONE;
SocTempC := TELEMETRY_NONE;
RSSIdB := TELEMETRY_NONE;
Result := False;
end;